  https://www.phoenixcontact.com/pi/products/2902002 10/16/2018???page? 1 ?/? 5 signal conditioner?-?mini mcr-2-i4-u?-?2902002 please be informed that the data shown in this pdf document is generated from our online catalog. please find the complete data in the user's documentation. our general terms of use for downloads are valid (http://phoenixcontact.com/download) 3-way signal conditioner with plug-in connection technology for the electrical isolation of analog signals. input signal: 4 ... 20 ma, output signal: 0 ... 10 v, screw connection technology product description standard signal 3-way signal conditioner with plug-in connection technology for the electrical isolation, conversion, amplification, and filtering of standard signals. the measuring transducer supports fault monitoring and nfc communication. key commercial data packing unit 1 pc gtin gtin 4046356651844 technical data note utilization restriction emc: class a product, see manufacturer's declaration in the download area dimensions width 6.2 mm height 110.5 mm depth 120.5 mm ambient conditions ambient temperature (operation) -40 c ... 70 c ambient temperature (storage/transport) -40 c ... 85 c input data number of inputs 1 configurable/programmable no current input signal 4 ma ... 20 ma zone 2 in sensor / field out plc / dcs 4-wire out i+ u s 5 6 1 2 pwr+ pwrC + + + C C C C + fm 1 5 2 6 3 7 4 8 in i+ out u+ tiC pwr+ pwrC in iC pwr+ pwrC out uC out i- power i u out in fm
https://www.phoenixcontact.com/pi/products/2902002 10/16/2018???page? 2 ?/? 5 signal conditioner?-?mini mcr-2-i4-u?-?2902002 technical data input data input resistance current input approx. 63 (+ 0.7 v for test diode) output data number of outputs 1 configurable/programmable no voltage output signal 0 v ... 10 v max. output voltage 11 v short-circuit current < 15 ma load/output load voltage output 10 k ripple < 20 mv pp (at 10 k) power supply nominal supply voltage 24 v dc supply voltage range 9.6 v dc ... 30 v dc (the din rail bus connector (me 6,2 tbus-2 1,5/5-st-3,81 gn, order no. 2869728) can be used to bridge the supply voltage. it can be snapped onto a 35 mm din rail according to en?60715)) typical current consumption 25 ma (24 v dc) 54 ma (12 v dc) power consumption 200 mw (at 9.6 v dc) connection data connection method screw connection single conductor/terminal point, solid, with ferrule, min. 0.2 mm2 single conductor/terminal point, solid, with ferrule, max. 1.5 mm2 single conductor/terminal point, solid, without ferrule, min. 0.2 mm2 single conductor/terminal point, solid, without ferrule, max. 2.5 mm2 conductor cross section flexible min. 0.2 mm2 conductor cross section flexible max. 1.5 mm2 min. awg conductor cross section, flexible 24 max. awg conductor cross section, flexible 12 stripping length 10 mm screw thread m3 general no. of channels 1 maximum transmission error 0.1 % (of final value) maximum temperature coefficient 0.01 %/k temperature coefficient, typical 0.01 %/k limit frequency (3 db) approx. 30 hz step response (10-90%) approx. 10 ms protective circuit transient protection electrical isolation reinforced insulation in accordance with iec 61010-1 overvoltage category ii zone 2 in sensor / field out plc / dcs 4-wire out i+ u s 5 6 1 2 pwr+ pwrC + + + C C C C + fm 1 5 2 6 3 7 4 8 in i+ out u+ tiC pwr+ pwrC in iC pwr+ pwrC out uC out i- power i u out in fm
https://www.phoenixcontact.com/pi/products/2902002 10/16/2018???page? 3 ?/? 5 signal conditioner?-?mini mcr-2-i4-u?-?2902002 technical data general degree of pollution 2 rated insulation voltage 300 v (effective) test voltage, input/output/supply 3 kv (50 hz, 1 min.) electromagnetic compatibility conformance with emc directive noise emission en 61000-6-4 noise immunity en 61000-6-2 when being exposed to interference, there may be minimal deviations. color gray housing material pbt mounting position any assembly instructions the t connector can be used to bridge the supply voltage. it can be snapped onto a 35 mm din rail according to en 60715. conformance ce-compliant atex ? ii 3 g ex na iic t4 gc x ul, usa/canada ul 508 listed class i, div. 2, groups a, b, c, d t6 class i, zone 2, group iic t6 certificate of classification dnv gl 14445-15hh fire protection for rail vehicles (din en 45545-2) r22 hl 1 - hl 2 fire protection for rail vehicles (din en 45545-2) r23 hl 1 - hl 2 fire protection for rail vehicles (din en 45545-2) r24 hl 1 - hl 2 emc data designation electromagnetic rf field standards/regulations en 61000-4-3 designation fast transients (burst) standards/regulations en 61000-4-4 designation conducted interferences standards/regulations en?61000-4-6 standards and regulations electromagnetic compatibility conformance with emc directive noise emission en 61000-6-4 standards/regulations en 61000-4-2 designation electromagnetic rf field standards/regulations en 61000-4-3 en 61000-4-4 en 61000-4-5 designation conducted interferences standards/regulations en?61000-4-6 electrical isolation reinforced insulation in accordance with iec 61010-1 conformance ce-compliant zone 2 in sensor / field out plc / dcs 4-wire out i+ u s 5 6 1 2 pwr+ pwrC + + + C C C C + fm 1 5 2 6 3 7 4 8 in i+ out u+ tiC pwr+ pwrC in iC pwr+ pwrC out uC out i- power i u out in fm
https://www.phoenixcontact.com/pi/products/2902002 10/16/2018???page? 4 ?/? 5 signal conditioner?-?mini mcr-2-i4-u?-?2902002 technical data standards and regulations atex ? ii 3 g ex na iic t4 gc x ul, usa/canada ul 508 listed class i, div. 2, groups a, b, c, d t6 class i, zone 2, group iic t6 fire protection for rail vehicles (din en 45545-2) r22 hl 1 - hl 2 fire protection for rail vehicles (din en 45545-2) r23 hl 1 - hl 2 fire protection for rail vehicles (din en 45545-2) r24 hl 1 - hl 2 environmental product compliance china rohs environmentally friendly use period = 50 for details about hazardous substances go to tab downloads, category manufacturer's declaration drawings pictogram block diagram pictogram zone 2 in sensor / field out plc / dcs 4-wire out i+ u s 5 6 1 2 pwr+ pwrC + + + C C C C + fm 1 5 2 6 3 7 4 8 in i+ out u+ tiC pwr+ pwrC in iC pwr+ pwrC out uC out i- power i u out in fm
https://www.phoenixcontact.com/pi/products/2902002 10/16/2018???page? 5 ?/? 5 signal conditioner?-?mini mcr-2-i4-u?-?2902002 approvals approvals approvals ul listed / cul listed / eac / gl / culus listed ex approvals atex / ul listed / cul listed / culus listed approval details ul listed? ? ? http://database.ul.com/cgi-bin/xyv/template/lisext/1frame/index.htm ?file e 238705 cul listed? ? ? http://database.ul.com/cgi-bin/xyv/template/lisext/1frame/index.htm ?file e 238705 eac? ? ? ?eac-zulassung gl? ? ? http://exchange.dnv.com/tari/ ?14445-15 hh culus listed? ? ? ? phoenix contact 2018 ? - all rights reserved http://www.phoenixcontact.com phoenix contact gmbh & co. kg flachsmarktstr. 8 32825 blomberg germany tel. +49 5235 300 fax +49 5235 3 41200 http://www.phoenixcontact.com zone 2 in sensor / field out plc / dcs 4-wire out i+ u s 5 6 1 2 pwr+ pwrC + + + C C C C + fm 1 5 2 6 3 7 4 8 in i+ out u+ tiC pwr+ pwrC in iC pwr+ pwrC out uC out i- power i u out in fm